CONTACT US

If you have any queries, get in touch today! Don't hesitate. We try to take the extra step for our customer satisfaction.

  • FirstName *

  • LastName *

  • Email *

  • Message

  • SEND

  • Security Code
    Refresh the code
    Cancel
    Confirm

0
INQUIRY

ONLINE INQUIRY MORE+
  • Contacts *

  • Mobile phone *

  • Information

  • Submit

  • Security Code
    Refresh the code
    Cancel
    Confirm

Inquiry Content:


You have no items to require

Centrifugal Water Chiller Double Unit

The ejector pump is used to recovery oil in low pressure side by medium pressure flash gas, without energy loss on water chiller.

Price Interview

Price Interview

Centrifugal Water Chiller Double Unit

Interview

Select the number of specifications

Please check the product information you want!

Product Detail

SANHER Centrifugal Water Chiller (double Unit)

Profile

● Cooling capacity of Sanher double unit centrifugal water chiller from 1500 to 2800 ton.

● Brand: SANHER or OEM

● Running Condition:

Evaporator: Water inlet/outlet temperature is 12℃/7℃

Condenser: Water inlet/outlet temperature is 30℃/35℃ (When running conditions different, please contact with us for detail parameter)

● The power supply options:

Low-voltage unit: 3φ-380V-50Hz

High- voltage unit: 3φ-6KV-50Hz,3φ-6.6KV-50Hz,3φ-10KV-50Hz


1(001)

 

Features and Advantages

1.Professional design

SANHER centrifugal chiller adopts Hanbell 2 stage centrifugal chiller.

2(001)

3

2.Reliable oil reclaim device-ejector pump

The ejector pump is used to recovery oil in low pressure side by medium pressure flash gas, without energy loss on water chiller.

4

3.Control components of refrigerant flow -orifice plate.

(1)Orifice plate is adopted as the refrigerant flow control device. Each orifice plate is designed in accordance with the unit's performance and reaches the most match of the unit.

(2)2-3 orifice plates are adopted as a set of throttling device. The first one is used as liquid seal and the rest are used to throttle and pressure drop, in order to adjust the refrigerant flow that the evaporator required , by the dynamic balance of refrigerant itself at full load, partial load and different conditions.

(3)As there are no moving parts of the orifice plate, its reliability is much better than all kinds of throttling valves of mechanical transmission.

5(001) 6(001)

When full load operation, liquid column height is H, and the static pressure generated by liquid column will deliver refrigerant required from the first orifice plate to the second one.

When half load operation, liquid column height is H/4, and the when refrigerant through the first orifice plate becomes half because of insufficient static pressure. There is flash phenomenon between two orifice plates generated by the up steam flow reduction. The refrigerant flow will decrease by half as liquid refrigerant mixed with large amount of flashing gas through the second orifice plate together.

 

Packing and Shipping

Plastic film+ Wooden box for exporting.

Ship by sea or by land


No comment

Product Detail

SANHER Centrifugal Water Chiller (double Unit)

Profile

● Cooling capacity of Sanher double unit centrifugal water chiller from 1500 to 2800 ton.

● Brand: SANHER or OEM

● Running Condition:

Evaporator: Water inlet/outlet temperature is 12℃/7℃

Condenser: Water inlet/outlet temperature is 30℃/35℃ (When running conditions different, please contact with us for detail parameter)

● The power supply options:

Low-voltage unit: 3φ-380V-50Hz

High- voltage unit: 3φ-6KV-50Hz,3φ-6.6KV-50Hz,3φ-10KV-50Hz


1(001)

 

Features and Advantages

1.Professional design

SANHER centrifugal chiller adopts Hanbell 2 stage centrifugal chiller.

2(001)

3

2.Reliable oil reclaim device-ejector pump

The ejector pump is used to recovery oil in low pressure side by medium pressure flash gas, without energy loss on water chiller.

4

3.Control components of refrigerant flow -orifice plate.

(1)Orifice plate is adopted as the refrigerant flow control device. Each orifice plate is designed in accordance with the unit's performance and reaches the most match of the unit.

(2)2-3 orifice plates are adopted as a set of throttling device. The first one is used as liquid seal and the rest are used to throttle and pressure drop, in order to adjust the refrigerant flow that the evaporator required , by the dynamic balance of refrigerant itself at full load, partial load and different conditions.

(3)As there are no moving parts of the orifice plate, its reliability is much better than all kinds of throttling valves of mechanical transmission.

5(001) 6(001)

When full load operation, liquid column height is H, and the static pressure generated by liquid column will deliver refrigerant required from the first orifice plate to the second one.

When half load operation, liquid column height is H/4, and the when refrigerant through the first orifice plate becomes half because of insufficient static pressure. There is flash phenomenon between two orifice plates generated by the up steam flow reduction. The refrigerant flow will decrease by half as liquid refrigerant mixed with large amount of flashing gas through the second orifice plate together.

 

Packing and Shipping

Plastic film+ Wooden box for exporting.

Ship by sea or by land


Centrifugal Water Chiller Double Unit
The ejector pump is used to recovery oil in low pressure side by medium pressure flash gas, without energy loss on water chiller.
Long press to look detail
Long by picture save/share
INQUIRY

ONLINE INQUIRY MORE+
  • Contacts *

  • Mobile phone *

  • Information

  • Submit

  • Security Code
    Refresh the code
    Cancel
    Confirm

Inquiry Content:


You have no items to require

Add Successfully

Centrifugal Water Chiller Double Unit

Enquiry
INQUIRY

ONLINE INQUIRY MORE+
  • Contacts *

  • Mobile phone *

  • Information

  • Submit

  • Security Code
    Refresh the code
    Cancel
    Confirm

Inquiry Content:


You have no items to require

Add Successfully

Related Products

Home             About Us             Products             Application            News             Contact Us   

 

 

OUR PARTNERS

Room 1801,

xxxBuilding,

Guangzhou,Guangdong

 

Copyright © 2025 Established All Rights Reserved.

OUR PARTNERS

Room 1801,

xxxBuilding,

Guangzhou,Guangdong

 

Copyright © 2005-2015 MySite Ltd. All Rights Reserved.

Service Center
Phone number
+86 157 1812 4557
WhatsApp
Andy:+86 157 1812 4557
WeChat
GLtec1
Qrcode
WeChat
添加微信好友,详细了解产品
使用企业微信
“扫一扫”加入群聊
复制成功
添加微信好友,详细了解产品
我知道了